3 DVD Players, 1 Controller
Brandspeak Communications (brandspeak.net)
planned their display with 4 plasma monitors, each showing a different
4-minute video, all of them playing and repeating simultaneously. One
solution would have been to use Pioneer DVD-7400 players with a
synchronizer, but the budget was already set and the firm already owned
3 JVC DVD players. Enter BCD.
At BCD, we reviewed Brandspeak's requirements and arrived at the
elegant solution of using one BCD VC-16b controller equipped with 4
infrared emitters. The JVC was not a machine we controlled so they sent
one to us for a day so we could learn its characteristics. We were
somewhat concerned that the little VC-16b would have enough power to
drive 4 IR emitters, but that proved to be a non-issue.
The controller and the 4 players were all on the same
power strip. Each DVD had a single different video. Brandspeak
programmed the DVD discs so that the PREVious command restarted the
video. With telephone guidance from BCD, Brandspeak programmed the
single controller with a command string similar to this:
>INI2 <a href="http://www.php.net/time"><span style="color: #000066">TIME</span></a> <span style="color: #cc66cc">300</span>; LOOP FOREVER; <a href="http://www.php.net/prev"><span style="color: #000066">PREV</span></a>; <a href="http://www.php.net/time"><span style="color: #000066">TIME</span></a> <span style="color: #cc66cc">2430</span>; LEND
- INI2 is the name of the command string that is issued when the VC-16b is first powered up (Cold Boot).
- Each unit of TIME is about a tenth of a second so when power was applied, the VC-16b waited 30 seconds for the discs to spin up.
- LOOP
can have a number to designate how many times to repeat subsequent
commands. FOREVER is a special parameter that goes... forever.
- PREV restarts all the videos
- TIME 2430 is about 4 minutes and 3 seconds... just enough time to let the videos finish.
- LEND means Loop END.
There are other ways to achieve absolute synchronization, but
Brandspeak reported that with this installation, the timing differences
between machines were unnoticed... about 1/4 second.
Note: 30 October 2003
- Marureen from Brandspeak emailed today wanting to change the command
string, so we told her. Her reply: "Reprogramed it and it works great.
Thanks."
Glad to help.
|